Esta norma especifica los requisitos de las fijaciones técnicas para tornillos y accesorios destinados a su uso con placas de yeso laminado, según la norma DIN EN 14566.

Dimensiones clave y parámetros técnicos

Dimensions in mm - source DIN 18182 1&2 Sizes, forms and application

Formen, Maße, Anwendung

Forme, dimensioni, applicazioni

Publication date: DIN 18182-1: 02/2015; DIN 18182-2: 02/2010
representation of the drywallscrews designation symbol head form thread style nom diameter d1 min dk max l b
TN trompet double continuos 3.5 3.4 8.5 25÷55
16÷30
4 3.7 8.5
4.3 4 8.5
double or single continuos 5.1 4.8 8.5 70÷130 45
5.5 5.2 8.5
TB trompet double continuos 3.5 3.35 8.5 25÷55 16÷30
SN countersunk double continuos 3.5 3.35 5.7 30÷35 21
FN round flanged double or single continuos 4.3 4 11.07 35 29
5.1 4.8 11.07
5.5 5.2 11.07
LB truss head as Din Iso 7049 double continuos 3.5 3.35 6.6 9.5 8.75

Clips - Klammern - Graffe

line clip type dn br ln a
1 A 1 to 1.3 5 to 8.4 29 to 32 ≤dn
2 B 1 to 1.3 8.5 to 11.5 29 to 40
3 C 1.31 to 1.49 9 to 12 35 to 40
4 D 1.5 to 1.6 9 to 12 37 to 65

Nails - Nägel - Chiodi

dn
symbol
dn
D min head diameter
l1 ringed section
l type G
L type R
shnak type plain (G)
shank type anular ringed (R)
2.2
22
2.2
5
5
≥ 8 x dn
28 -50
37 - 50
2.5
25
2.5
5.5
5.5
≥ 8 x dn
30 - 70
40 - 70
2.8
28
2.8
6
6
≥ 8 x dn
41 - 70
52 - 70